| 046/1997 | 02/15/97 | 20:47 Recover from uncommanded reset. Did a reset, a reload of all patches to this point, and a HV ramp. |
| 049/1997 | 02/18/97 | 16:38 Abbreviated pulser test run. Table 1-10 only. |
| 081/1997 | 03/22/97 | FOT turned PSI off via _poff procedure; no PI team interaction. Solo for FC team for turning PSI off. |
| 084/1997 | 03/25/97 | First use of _ign2.prc for PSI ignition. Heater is turned off then keeper set to level 2. |
| 101/1997 | 04/11/97 | 19:59:58 STID_HVMOFF. TIDE high voltage off for spin flip. |
| 105/1997 | 04/15/97 | 22:17 Loaded patch to run autosensitivity from stops only rather than stops and start converts. |
| 105/1997 | 04/15/97 | 22:30 Began TIDE post spin flip high voltage ramp. |
| 134/1997 | 05/14/97 | Ran PSI with EFI in low impedance mode. Don Thompson suggested run. |
| 149/1997 | 05/29/97 | Started PSI continuous run for 13 days, 24 hours a day. Mode is to run 2 weeks on, 8 weeks off. First use of _ign3.prc for ignition. |
| 183/1997 | 07/02/97 | 18:00 Changed mass table to tidmtfltcal1. Changed H+ defn to go from 0 to 31 (moved lower limit from 8 to 0). (These mass changes put TIDE back in configuration prior to Feb reset.) Changed threshold 0 from 10 to 20 cts/sample. Changed priority to 4 0 3 (stops,H+,O+). Changed reporting to fixed ions 4,0,3 (stops,O+,H+). Disabled Sector 0 direct events reporting(to save TM space). |
| 206/1997 | 07/25/97 | First run through the radiation belt with setback voltages on the mcps at 1200 V. Mirror had to be open via opt_a_s_ena command. |
| 225/1997 | 08/13/97 | 13:27 Started 2nd PSI continuous 14 day run. Took 3 trys and change of procedure. Problem is apparently 5 sec wait in _ign3.prc. |
| 239/1997 | 08/27/97 | 13:10(?) PSI off |
| 286/1997 | 10/13/97 | 15:03:46 STID_HVMOFF. TIDE high voltage turned off for semi-annual spin flip. |
| 290/1997 | 10/17/97 | TIDE high voltage ramped up. |
| 309/1997 | 11/05/97 | 13:32:24(?) Started 3rd continuous run of PSI. Took 2 attempts. Keeper current was lowest ever on startup ² 300 mA, while keeper voltage was about 40 V. Wait in proc is 19 seconds. Used hard wait on second try. |
| 310/1997 | 11/06/97 | 15:00 Large geophysical disturbance. Mirrors to lowest setting and stayed there to 311 about 15:00 UT. No gnd ops during this time. |
| 322/1997 | 11/18/97 | 21:02:21 PSI off. |
| 324/1997 | 11/20/97 | 01:15 Uncommanded reset on TIDE 20:36:46 STID_HVMOFF issued to TIDE. High voltages changed from armed to safe. |
| 328/1997 | 11/24/97 | 16:45- Recovery operations and high voltage ramp. TIDE back online by 19:45. Sweep table is with sensitivity level of 7. Correct sweep table to load in first radiation belt pass. |
| 344/1997 | 12/10/97 | STOP MCP voltages back to 1242 V.Since the 11/20/97 reset it has been 1233 V. |