| 038/2006 | 02/07/06 | 19:00 - HV shutdown for Polar trim. |
| 041/2006 | 02/10/06 | 20:35-21:24 - HV ramped to radiation belt levels after Polar trim. Ramp completed from stored command table at 01:23 on 02/11. |
| 106/2006 | 04/16/06 | 08:45 - Problem with mirror shutdown and TIDE science telemetry. TIDE's HV was shut off, the instrument reset, patches re-loaded, and HV ramped to radiation belt levels on 04/18, 13:32-15:11. Ramp completed from stored command table at 16:03. |
| 108/2006 | 04/18/06 | 20:11 - Polar GTM upset. Satellite reset at 07:43 on 04/19. TIDE came back up after the reset with no problems. |
| 237/2006 | 08/25/06 | Radiation Belt L-Shell Cutoffs changed from 6.0 (np-eq) to 6.0 (eq-sp) and 7.5 (sp-eq) to 6.5 (eq-np) to 6.5 (np-eq) to 6.5 (eq-sp) and 7.5 (sp-eq) to 6.5 (eq-np). |
| 271/2006 | 09/28/06 | Start MCP voltage was ramped from -2600V to -3400V at 21:42 to 21:55 and left there until 23:03 when the voltage was returned to -2600V. A significant increase in the TOF ion count rates was seen. |
| 279/2006 | 10/06/06 | 10:35 - Changed the Start MCP voltage from -2600V to -3400V. Started reporting H+, O+, and He+ in addition to Stops. |
| 310/2006 | 11/06/06 | 11:45 - HV shutdown for Polar spin axis adjustment. |
| 317/2006 | 11/13/06 | 16:13-17:07 - HV ramped to radiation belt levels after Polar maneuver. Ramp completed from stored command table at 17:25. |
| 355/2006 | 12/21/06 | Beginning at 05:45, the start MCP voltage changed from -3400V to -3000V. |
| 363/2006 | 12/29/06 | Starting with radiation belt commands at 13:18 UT on 12/29/06, TIDE mirrors shutdown and never came back up. Prior to the shutdown, starting at ~09:00 UT, the mirrors stepped down due to high counts. The high voltage was turned off at 14:02 on 01/03/07. TIDE was reset, software patches were loaded, and the high voltage ramped to radiation belt levels from 16:02-17:10 on 01/04/07. The ramp was completed from stored commands at 18:40. |