| 003/2007 | 01/03/07 | Starting with radiation belt commands at 13:18 UT on 12/29/06, TIDE mirrors shutdown and never came back up. Prior to the shutdown, starting at ~09:00 UT, the mirrors stepped down due to high counts. The high voltage was turned off at 14:02 on 01/03/07. TIDE was reset, software patches were loaded, and the high voltage ramped to radiation belt levels from 16:02-17:10 on 01/04/07. The ramp was completed from stored commands at 18:40. |
| 009/2007 | 01/09/07 | 13:30 - HV shutdown for Polar trim. |
| 012/2007 | 01/12/07 | 12:37-13:37 - HV ramp after Polar trim. |
| 026/2007 | 01/26/07 | 01:40 - TIDE telemetry spin packets stopped being reported in the Polar telemetry data, possibly the result of a GTM upset. 14:30-15:02 - HV was turned off, TIDE was reset, software patches were loaded, and TIDE was set up for the HV ramp. HV was ramped on 01/29, 15:15-16:31. |
| 057/2007 | 02/26/07 | 13:20 - HV shutdown for Polar maneuver. |
| 064/2007 | 03/05/07 | 16:45-17:38 - HV ramp after Polar maneuver. |
| 108/2007 | 04/18/07 | 06:30-15:28 - There was a shift in the TIDE spin angle bins. The initial shift was sometime during the 04:17 - 06:35 radiation belt pass. It corrected itself at ~15:28. |
| 124/2007 | 05/03/07 | 15:15 - Errors in the IMP RAM and ROM caused TIDE's high voltages to drop to zero. At the same time, the high angle resolution mode was enabled and a phase shift started. TIDE's high voltage was turned off at 20:21. TIDE was reset and software patches were loaded on 05/04, 13:40-14:27. The high voltage was ramped on 05/07, 15:38-16:28. |
| 135/2007 | 05/15/07 | 04:00 - Due to low power outout on Polar, TIDE was turned off. |
| 155/2007 | 06/04/07 | 18:15:41 - Low voltage turned on. 18:20 - 18:42 patches loaded. Satellite power output improved. Solar Zenith Angle past maximum and decreasing. |
| 156/2007 | 06/05/07 | 19:47 - high voltage ramped 19:47 - 20:28 UT. |
| 233/2007 | 08/21/07 | 14:35 - high voltage turned off in preparation for planned spacecaft flip. |
| 239/2007 | 08/27/07 | 19:53 - high voltage ramped 19:53-20:45 UT. |
Last Updated: September 19,2007